Pneuclean Filter Systems

Pneuclean Filter Systems

The Pneuclean unit is designed to remove microscopic particles generated by blowers during pneumatic conveying of contaminant-sensitive dry bulk products. Contaminants such as Iron and Hydrocarbons are produced by blowers and can adversely affect dry products such as plastic pellets and food materials.

These filter units are typically used on dry bulk tanker trucks and placed after the blower and before the bulk storage tanker. This in-line pneumatic system is also suitable for industrial applications or wherever microscopic filtration (up to 4 microns) of impurities is required.

Standard units employ 4″ inlets and outlets. However, 3″ plumbing can be used with available weld-on 4″x3″ female NPT adapters.

Special cartridge-style filter elements have a typical life expectancy of approximately 12 months or 2000 hrs. of service.

In-Line High Pressure Air Filtration for 4″ Air Lines
  • FDA Medium with 99.99% maximum efficiency at 4 microns
  • Maximum air flow 1000 CFM’s
  • Back pressure only .05 PSI
  • Temperature range -45° to 450°F
  • Average 12 month filter cartridge lifespan
  • Quick release V-clamp for easy inspection
  • Overall weight 16 lbs.
PneucleanTM Canister
Part Description
PC5000- PneucleanTM canister / filter
schedule 40 pipe inlet and outlets

PC5000AA- PneucleanTM canister / filter
schedule 4″ cam adapter inlet and outlets

PC5000VV- PneucleanTM canister / filter
4″ victaulic inlet and outlets